Frigosystem offers its customers a wide range of thermoregulation control units, which allow to regulate the temperature of the working fluids of process in a wide range of temperatures, ranging from 20°C up to 300°C. Depending on the required working temperature, working fluids can be of different types. Generally the most used fluids are: water, demineralized water, glycol water, diathermic oils, silicone oils.

The thermoregulation of the fluids inside the control units is achieved through the combination of a cooling system (direct or indirect) and a heating system with electrical resistances. These have the purpose of increasing the working fluid temperature that will be used as heating vector for the customer’s industrial process.

The electrical resistances must be carefully designed and selected so as not to damage the fluid that they heat. Each fluid, in fact, has its own critical temperature that must never be exceeded to avoid damaging the properties and the physical composition of the fluid itself.

The parameter to monitor and pay attention is the skin temperature, i.e. the temperature of the surface in contact between the resistance and the fluid. This depends on:

  • Outlet required fluid temperature.
  • Surface load (W/cm2).
  • Type of fluid to be heated.
  • Fluid velocity.


As regards to diathermic oil, this parameter must be much lower than that of the water, because cracking phenomena in the fluid itself can be triggered. The cracking phenomenon consist in the carbonization of the oil, which gives rise to the formation of encrustations of the deteriorated oil on the surface of the resistance. It is easy to understand that this phenomenon reduces the efficiency of the resistance to transfer heat to the fluid (due to the increase of the surface thermal resistance) and, consequently, causes the resistor itself to burn.

To avoid these problems, Frigosystem designs its resistances in order to have a specific load (measured in W/cm2) suitable for the working fluid. Moreover, the resistances are equipped with systems for limiting the maximum temperature of the fluid, in order to prevent damage.

With the same electrical power, the resistances with low surface load values require larger exchange surfaces. This means that we have a higher plant cost, as initial investment cost. Despite this, these measures allows us to have two big benefits: the lengthening of the useful life of the resistance (and of the control unit) and the reduction of unit downtime due to the breaking of the resistor.

Close Popup

This site uses cookies to manage navigation, personalize content, and analyze traffic. By closing the banner, you consent to the use of technical cookies only. This choice can be changed at any time.

Close Popup
Privacy Settings saved!
Settings

When you visit a website, information may be stored or retrieved and saved in your browser's cache, mainly in the form of cookies. Check your cookie settings here.

These tracking tools are strictly necessary to ensure the functioning and provision of the service you have requested from us and, therefore, do not require your consent.

Strictly necessary cookies
These cookies are set by Google's reCAPTCHA service to identify bots in order to protect the website from malicious spam attacks and to test whether the browser is capable of receiving cookies.
  • wordpress_test_cookie
  • wp_lang

Acceptance/Rejection of GDPR
These cookies store the choices and settings decided by the visitor in accordance with the GDPR.
  • wordpress_gdpr_cookies_declined
  • wordpress_gdpr_cookies_allowed
  • wordpress_gdpr_allowed_services

Decline all services
Accept all services
Open Privacy settings